Technical data: Power consumption: max. 5 A / 250 V (AC). Power consumption micro switch max. 700 mA / 250 V (AC). Nominal voltage pulse: 4 kV Drive type: linear drive Maximum stroke drive: 3.5 mm Nominal voltage: 230 V AC (+10% / -15%) Frequency: 50/60 Hz Power consumption: 2.0 W in continuous operation Design: NC (closed without current) 2-pin Running time: 3-5 minutes. Protection class: IP 54 Electrical protection class: II Connection cable: length 0.8 m Ambient temperature: 0°C~50°C Storage temperature: -25°C ~ 60°C. Mechanical connection: threaded ring M 30 x 1.5 Use: The actuator works according to the on/off principle and is usually controlled via a room thermostat. Operation: When mounted actuator, the valve is closed and has no flow. When powered on the actuator, the thermocouple heats up, expands and leads to linear movement. of the valve pin that opens the actuator and allows the flow. When the power is switched off, the valve closes thanks to the spring force. On the upper part of the actuator there is a lifting indicator, the lifting indicator whether the valve is open. Installation: 1. Remove the building protective cap or hand wheel of the valve. 2. manually screw the ring nut of the actuator onto the valve thread and block it. 3. Make the electrical connections according to the wiring diagram. 4. Attach the connection plug to the actuator. Please note that even in the event of a defective does not open, there is a risk of personal damage.